Strike Water
When hot water meets cool grain, the grain soaks up heat and the mixture settles well below the temperature of the water you poured in. Strike water is the water you heat for that first mixing, and getting its temperature right is what puts the mash on its target rest temperature instead of several degrees under it. This tool uses Palmer's initial-infusion equation from "How to Brew", in its metric form, to work out both the temperature and the volume: how hot the water needs to be, and how many litres to heat, for your grain weight, grain temperature, target mash temperature and water-to-grain ratio.
The equation assumes a warm vessel that draws no heat of its own. A cold pot or cooler will pull several degrees out of the mash, so fill it with hot water, let it sit a few minutes, and drain it before mashing in — or aim a degree or two above the calculated strike temperature and correct by stirring.
Palmer's equation, and why the water starts hot
The equation is a heat balance. The grain has to be warmed from its storage temperature up to the mash temperature, and the only heat available is the extra heat carried by the strike water above that same target. Dry grain holds much less heat per degree than water does — its specific heat is about 0.4, against water's 1.0 — so a kilo of grain needs the heat of about 0.4 litres of water to rise one degree. The equation turns that into a temperature: strike water temperature = (0.41 ÷ R) × (target − grain temperature) + target, where R is the water-to-grain ratio in litres per kilo. The 0.41 is the grain's heat-capacity constant in metric units, converted from the 0.2 Palmer uses with quarts per pound. Strike water volume is simply the ratio times the grain weight.
The ratio is what decides how far above the target the water must start. With a thick mash there is little water to spare heat from, so each litre has to carry more of it: at 1 L/kg the overshoot is about 0.41 times the gap between grain and target, while at 4 L/kg it is only about a tenth of that gap. That is why a thick single-infusion mash at 1.25 qt/lb (about 2.6 L/kg) wants water roughly 7 °C above the target, and a thin full-volume mash barely 3 °C above it. The grain weight itself does not appear in the temperature equation — only the ratio matters — because doubling the grain doubles both the heat the grain needs and the water that supplies it. Grain weight matters only for the volume.
Two things the equation does not cover are worth knowing. It assumes the mash vessel is already at temperature and absorbs nothing; in practice a cold steel pot or an uninsulated cooler can cost you 1–3 °C, which is why preheating matters more than the last decimal of the calculation. And the metric constant 0.41 is a rounded conversion of Palmer's 0.2 — the exact conversion is 0.417 — so the metric answer and the imperial answer for the same mash can disagree by a fraction of a degree. A few sources use the raw specific heat 0.4 instead, which shifts the answer by a similar amount in the other direction. None of that matters in practice: stir the mash thoroughly for a full minute after doughing in, then read the temperature in the grain bed rather than in the loose water on top, and adjust with a splash of boiling water or cold water if you are a degree off.
The tool refuses a few inputs rather than giving a misleading answer. A target at or below the grain temperature cannot be reached by heating water at all, since the strike water would have to be cooler than the mash. Ratios below 1 L/kg are thicker than any workable mash, and ratios above 10 L/kg are thinner than any mash that needs this calculation. And if the equation asks for water hotter than 100 °C — a very thick mash with very cold grain — no kettle can deliver it, so the tool says so and suggests a thinner mash or warmer grain instead.