Strength by Boiling Point Calculator
Alcohol pulls the boiling point of a wash down, so the temperature on the thermometer carries a clue about what is in the boiler: a wash rolling at 92–93 °C is roughly a 10% wash, and one creeping up towards 99 °C has nearly run dry. This tool works that clue backwards — give it the temperature you saw, and it estimates the strength. It is a handy cross-check while a run is going, but it is a rough guide, not a measurement: a hydrometer or alcoholmeter reading on a cooled sample tells you the strength far more precisely, and at high strengths this method stops working altogether. The page says where, and why.
Up here the boiling point barely moves as the spirit gets stronger — between 88% and the azeotrope it shifts only about 0.06 °C per point of ABV, so a half-degree thermometer error swings the answer by eight points or more. The figure above is a lower bound, not a reading: treat the liquid as strong spirit and check it with an alcoholmeter.
A boiling point this close to water's means only a percent or two of alcohol is left. At this end a half-degree thermometer error is a large share of what little signal there is, so take the figure as "almost nothing left" rather than a precise strength.
A thermometer is a rough guide, not a measurement. The number above is an estimate with a real margin of error, shown in the sensitivity row. For a strength you can rely on — for cuts, for proofing, for anything you will drink or sell — cool a sample and read it with a hydrometer or alcoholmeter instead.
How the numbers are worked out
The estimate comes from the ethanol–water boiling curve, the same one the boiling-point tool uses in the forward direction: at sea level pure water boils at 100 °C, a 10% wash at about 92.4 °C, and the azeotrope — 97.23% alcohol by volume, the strongest mixture any ordinary still can reach — at 78.15 °C. Between water and the azeotrope the boiling point falls steadily as the strength rises, so the curve can be run backwards: this tool narrows in on the strength whose boiling point matches the temperature you typed in, halving the search range again and again until it lands within a fraction of a degree. That is the whole calculation — no new physics, just the same curve read in the other direction, which is why the two tools agree when run against each other.
Altitude and weather shift every boiling point, so the tool adjusts the curve before it searches. Height above sea level is turned into air pressure with the standard atmosphere equation, and the boiling point at that pressure follows from the Clausius–Clapeyron relation, which ties boiling temperature to pressure through the heat needed to turn the liquid into vapour. It is the same correction the boiling-point tool applies, and the water numbers line up with the published table: water comes to the boil at 98.9 °C a thousand feet up, and at 90.6 °C nine thousand feet up. Skip the correction and a mountain reading will look stronger than it really is — the thin air, not the alcohol, did part of the work.
The hard limit is the flat top of the curve. Below about 40% a degree of temperature covers only a few points of strength, so a thermometer is genuinely informative. Above 85% the curve goes nearly horizontal: from 88% to the azeotrope the boiling point moves just 0.55 °C across nine points of strength, so a thermometer that is half a degree out — normal for a cheap probe — lands the answer eight points away from the truth. Worse, pure ethanol actually boils slightly hotter than the azeotrope (78.37 °C against 78.15 °C), so above the azeotrope the curve turns back on itself and one temperature can mean two strengths. The tool therefore stops at the azeotrope, 97.23%, and flags anything at or above 85% as unreliable: up there, only a hydrometer can tell 90% from 95%.
The low end has the opposite problem. A wash boiling at 99 °C is about 1% alcohol, and one at 99.5 °C about half a percent — the curve is steep down here, but there is almost no alcohol left to measure, so a small thermometer error is a big share of the answer. Read a near-100 °C result as "the boiler is spent" rather than as a strength. And remember what the thermometer is actually sitting in: a probe in the liquid reads the liquid's boiling point, which is what this tool needs, while a probe mounted high in the column sits in vapour instead, which runs cooler and would make the wash look stronger than it is.