Heating / Boil Time Calculator

Heat-up is the quiet part of a run day — nothing comes out of the still, but the clock is running and the meter is turning. This tool works out how long a charge takes to reach boiling from its volume, starting temperature, element power and strength, with an allowance for the heat that escapes to the room instead of warming the wash. It covers the heat-up only: once the wash is boiling, turning liquid into vapour takes far more energy again, and that is a different calculation.

The amount of wash in the boiler for this heat-up.
Room-temperature wash is about 20 °C; wash straight from a cold garage or shed can be much lower.
The power you heat up at — many distillers heat up at full power and turn down once boiling starts.
Typical wash 8–12%. Stronger charges boil at lower temperatures, so they need less heat-up time.
Heat lost through the boiler walls and lid. 20% is a rough middle figure; an insulated boiler loses far less, a bare boiler in a cold room loses more.
Heat loss is a guess — measure your own rig if it matters.

No published figure fits every boiler: insulation, boiler size, room temperature and draughts all change it. If your heat-ups consistently run longer than this tool predicts, raise the allowance; if they run shorter, lower it. The allowance is the biggest uncertainty in the answer, bigger than any of the physics below.

Boiling point of the wash—
Mass of wash—
Energy required—
Effective power (after heat loss)—
Time to reach boiling—

How the time is worked out

The energy needed is mass times specific heat times temperature rise: the wash mass comes from its volume and its density at 20 °C (a 10% wash is about 0.985 kg per litre, slightly lighter than water), the temperature rise is the gap between the starting temperature and the wash's boiling point, and the specific heat used is water's 4.186 kJ per kilogram per degree. The boiling point comes from the ethanol-water boiling curve — a 10% wash boils at about 92.4 °C rather than 100 °C, which is why a wash reaches boiling sooner than the same volume of water would. Dividing the energy by the effective power — the element power minus the heat-loss allowance — gives the time.

Using water's specific heat for the whole wash is an approximation, and it is worth knowing which way it leans. Ethanol's specific heat is only 2.44 kJ per kilogram per degree, well below water's, so a real wash needs slightly less heat than the water figure suggests — about 3% less for a 10% wash, and more for a stronger charge such as low wines. The tool keeps the water value because the difference is small next to the uncertainty in heat loss, and because the error is on the safe side: the real heat-up runs a little faster than the figure shown, never slower.

It also helps to keep heat-up in proportion. Warming a litre of water from 20 °C to boiling takes about 335 kJ; actually boiling that litre away takes about 2256 kJ, nearly seven times as much. So the heat-up is the cheap part of a run day — most of the energy goes into turning liquid into vapour once boiling starts, which is why a run takes hours after a heat-up of an hour or so. The practical levers on heat-up time are a bigger element, a smaller charge, and insulation: lagging the boiler is the cheapest of the three, and it keeps paying off through the whole run by cutting the heat loss that this tool asks you to allow for.

See also: Boiling Point Calculator, Vapour Speed, Strip Run Planner, Safety.